<LOGO>
FM Transmitter Measurement Report
Created: 2023-11-27 20-19-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 63 dBuV RIRE &
Pilot RDS Phase Difference
7.1 kHz 3.9 kHz 61 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
9 kHz 65 kHz 19120 0,0418
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
4,0 dBr 6,08 dBr 7,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 20:19, 27.11.2023
RT
"RIRE : PHIL COLLINS PHILIP BAILEY "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (63 dBuV) Max at: 65 kHz MIN: 9 kHz % above 75 kHz: 0,0418 Acquired: 2023/11/27 20:18:50 Total samples: 19120 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,7 dBr MIN: 4,0 dBr AVE: 6,08 dBr % above 10,0 dBr: 0,0 Last value: 7,2 dBr (2023/11/27 20:18:49) Station: 101.50 MHz, signal: 5/5 (63 dBuV) 20:04 20:06 20:08 20:10 20:12 20:14 20:16 20:18 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality